pci-7344. 12-10-2002 05:13 AM. pci-7344

 
 12-10-2002 05:13 AMpci-7344  It is connected to a UMI-7764 breakout box

. I encountered problems controlling the motor with MAX using a digital signal. An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and. . Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. For my research purpose I need some important information from you. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. Go to the Axis Configuration option, under the desired axis (e. Bgrain, there is no way to tweak a PCI-7344. Analog Output Device. 10-27-2001 03:20 PM. 10-02-2007 06:58 AM. PCI-7344 Controller module PCI-7344 Controller module Module Clips Drive controller servo motor Contact: Mr. 25 ms corresponding to 0 degrees, 1. 445 subscribers. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. and PCI-7344 motion controller to implement a modular control application that works with an existing robot and four-axis driver. These devices run the PID loop onboard in realtime and you only need to set parameters like travel distance, speed and acceleration. 1. Axis 1) In the Axis Configuration tab, set Type to Stepper. Return to Home Page; Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. But the MAX couldn't read the current traject. I have. If you select the Firmware tab, there should be a button near the top of the screen callled "Update Firmware" If the firmware is up to date, it will be grayed out. Product Support, I have recently been using a FW-7344 motion controller to drive an experiment. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Bgrain, there is no way to tweak a PCI-7344. PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. TheSee all Driver Software Downloads. . This is one of true pains of maintaining legacy systems. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. National Instruments PCI-7344 Motion Controller Device. I have one 3 axes(X,Y,Z) mchine. PCI-7390 Driver. All of 3 motors require +5V 24mA for the Mike encoder. Send documents to the printer connected to your host computer or to the printer connected to the computer you are. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. To guarantee the delay-free commands flow we use the programmable FPGA device present on the NI-Motion PCI-7344 stage controller board. I don't see a good way to control 5 motors with this board. Applications Engineering Group. PCI-7344 was listed as an obsolete card already. zip" has been downloaded 223 times with a user rating of 5 out of 5 stars, based on 10 reviews. . including the MAX setting. The change was part of an improvement to the manufacturing process for. The PCI-7344, PXI-7344, and PCI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. 3003 DSP from 7. Sacha, with the built in controller all you have to do is to wire a serial cable to the serial port of your PC and the drive and use VISA functions to send ASCII commands to the device. ConventionsCan I use two NI - PCI 7344 motion controllers in one PC. 20. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. all controllers in the 7344/7334 family. Re: PCI-7344 motor interfacing help. The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. . FlexMotion 5. In addition, a PCI network card connects this MPVIEW to the Internet through the local area network (LAN). The "Encoder Index found" led is green. . Current PC config is: Pentium 4 - 2. 75 ms. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). Find many great new & used options and get the best deals for National Instruments PCI-7344 Servo Controller Card at the best online prices at eBay! Free shipping for many products! I am a Master’s student of International Islamic University Malaysia. "The polarity of the trigger input is programmable in software as active-low (inverting) or active-high (non-inverting), rising or falling edge. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. Not all NI Motion controllers can control a step motor, but the following can: PCI-7332, PXI-7332, PCI-7334, PXI-7334, PCI-7342, PXI-7342, PCI-7344, PXI-7344, PCI-7352, PXI-7352, PCI-7354, PXI-7354, PCI-7356, PXI-7356, PCI-7358, PXI-7358, and PCI-7390. 3003. My application requires 6 axis and hence I want to use two PCI 7344 motion controllers. So, am I missing something ?, All the motors are 3rd Party. Page 2 Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. the PCI-7344 or PCI-7342 board. I am using PCI-7344 control card with MID-7654 amplifier driving a three axis dc motor servo system. It is related to 3D printer. The change was part of an improvement to the manufacturing process for. 1. I need to be able to read the RPM of an encoder. -While controlling the motors in the "Interactive control" tab, the position. On 2 different systems and 2 different motion control cards (pci-7334 and 7344) after running the cards for approximately 30 minutes I get errorThe PCi 7344 can control a brushless servo provided that the drove for your motor can take a +/- 10 volt torque signal or a step and direction signal as a command signal. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. It looks like the umi-7774 connected to the motor drive only with 2 pins from the Control connector (pin#1 and pin#9) and the Encoder of the servo connected to few pins in the Feedback connector and thats it. Refer to the Glossary section of this manual for definitions of selected related terms. We have been trying to control the velocity and position of our servomotor but regardless of what values we put in the motor always moves at about 500 rpm and travels about -31000 cnts before stopping. Return to Home Page; Toggle navigation; Solutions. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. Page 1 PCI-7334. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. 10. It breaks out the signals available from the PCI-7344. For my research purpose I need some important information from you. 2. 4-Axis, Stepper Motion Controller Device—The PCI‑7334 is designed for point‑to‑point motion applications. We have successfully done several projects using the Parker-Compumotor Gemini GV servo drive and the NI-7344 and the NI UMI-7764 breakout box. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. command This is one of the commands described below. 展开 NI 运动设备 树. Can I configure another one in the same PC to add more axes to my current system. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. The marking triggering signal (TTL) generated by a rotary encoder is applied to the trigger input of the NI-MID 7604 module trough a delay circuit (2) and a logic gate (AND) of SPUC. Provides support for NI data acquisition and signal conditioning devices. 25 ms to 1. rules. My email id is sy. The PCI‑7344 also provides contouring capability for complex moves. Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Instruments PCI-7344 (Part number: 778916-04) is a high-quality Motion Controller for stepper/servo control applications. 能否用NI运动控制卡读取非正交编码器? 硬件: Motion Control>>Controllers>>PCI-7344, Motion Control>>Controllers>>PXI-7344, Motion Control. PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. Go to the Axis Configuration option, under the desired axis (e. Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. Unfortunately my FW-7344 has malfunctioned and my supervisor has asked me to research other options to have it replaced. I am currently working on a project related to nanomotion stage control using PCI-7344 and LabVIEW 6. 0. Configure your stepper settings. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. The 7340 uses the same configuration and runs the same firmware as the 7344. PCI-7344 NI module PCI-7344 NI module Module Clips Drive controller servo motor Contact: Mr. Knight of NI. vi as a starting point, I programmed my data acquisition vi to start when the Check Blend Complete. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. Software Changes: All of these settings are at Device and Interfaces >> NI-Motion Devices >> Default 73xx Configuration >> Axis x >> Axis Configuration >> Stepper Settings . Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. flx and Read Trajectory Data. Currently the only terminal block we have is SCB-68, and we will need to use the motion I/O port of the PCI-7344. I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. The 7344 can do a frequency of 40 Hz or 78 Hz (which either may or may. comHi,All I use NI PCI-7344,UMI-7764 and servo motor in my project. Servo motors expect a pulse every . vi twice for both the Hardware and Software limits. I recently upgraded to MAX version 2. . FlexMotion 5. TheI want to install a FlexMotion PCI 7344 (6 axes), so I need the drivers and library but I don´t know which version can I use. Hope this helps, Jorge M. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. This works fine while no other process on the PC is running. Hello, I have been using a PCI-7344 motion controller along with LabView to control a 3-dimensional motor/slider system. 11 PCI 7344 MAX One-axis Configuration 39 3. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. I've created a program that uses motion control and digital I/O via the PCI-7344 Motion Control card. JB. 0 and earlier. When i try to autotune, the servo motor goes berserk, so I have to manually tune it with "Step response". Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. 08-21-2009 03:04 PM. The trigger frequency should be very high (> 4 kHz). 20. . The PCLK (or Pulse Clock) line can also be used to input your own clock which is divided down by 256 or 32,768 depending on what you select in. 付属されていた新しいドライバCDはインストールしましたでしょうか?. The Problem is feedback from each axis (AZ & EL). 8 degree pitch (200 steps per rev). For my research purpose I need some important information from you. Feel free to check it out here. This will allow you to change the board ID for your hardware so that you can use it to match the configured ID in your code, or. Fault- The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. You willI have a E-Stop button on my machine. . I am using a 4096 step per revolution encoder with a UMI-7764 connected to a PCI-7344. 客户使用pci-7344,umi-7764连接第三方的电机和驱动器,搭建了一个闭环控制系统,但发觉电机编码器反馈回的值有些问题. Please let me know if you have any additional questions on this issue. But to my surprise the output is not matching the required data. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming. Indeed, when we use a newer PCI7344 card, we have driver / firmware compatibility issues. It is related to 3D printer. flx"; the 2nd step is to run. . 问题:. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. Essential details:PCI-7344 NI Motion Controller Device Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National. Manufacturer: National Instruments FW-7344, 4 Axes, 9 to 25 VDC, Stepper/Servo Motion Controller National Instruments FW-7344 Stepper/Servo Motion Controller The FW-7344 (Part Numbers: 186839C-01, 778113-01) is a Stepper/Servo Motion Controller. National Instruments PXI-7344 Stepper/Servo Motion Controller Module. . STL file there are 28 layers/faces. 0 Kudos Message 1 of 7 (4,209 Views) Reply. it is going to be sqaure wave signal . . Dennis_Knutson. 04-26-2021 10:40 AM. hwdb hwdb/20-pci-vendor-model. Shipping and handling. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). Member. The 7334 controllersThe solutions that I have proposed are of course much more complex than using a PCI-7344 motion controller as all the software layers that are present in the firmware of the PCI-7344 need to be implemented in software. The onboard CPU uses an embedded real-time OS. Problem 1 The encoder counts up and down ok but gives 4096 counts between z pulses and not 1024. The 7340 uses the same configuration and runs the same firmware as the 7344. Unless otherwise noted, text applies to all controllers in the 7344 family. National Instruments - PCI-7344 repair options: Standard Repair - Up to 10 workings days* Emergency Repairs - Up to 3 working days. I initialise it using NI MAX (version 2. Maybe adaptive algorithm, or some other algorithm which I invented. Page 37: Analog Inputs. dll well with vc,but when I use it under rtx ,it does not work,appering " can not load the driver". Looking to measure speeds up to 500 RPM. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. The PCI-7344 motion controller card also included analog and digital outputs, which we use to control the spray nozzle, the gas flow valve, the multi-port solenoid valves, and the fan. But i >want to do it automatically in a VI. After un-installing all NI software I now find that I cannot get the system to recognize the PCI-7344 board. PCI-7390 Driver. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. jspaarg. Along with this, I want to record motion/motor position data into the same file, whenever I give a move (sinusoidal) command. When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. The reason for the 64-bit operation is a 3rd party function generator card that requires 64-bit LabView to work in conjunction with the 64-bit drivers. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. Go to the Axis Configuration option, under the desired axis (e. The total. Buy PCI-7344: Graphics Cards - Amazon. . 6: Cấu trúc của máy phay CNC. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. 1 were installed. How do I do that? Hopefully, there is also a way for me to h. I would appreciate if you can suggest me any research that I could do on this system which involve 3 axes motion -using all ac servo motor (automated storage and retrieval system) - I. My pr. PCI-7344. Axis 1) In the Axis Configuration tab, set Type to Stepper. Options. I have PCI-7344 and PCI-6023E and I want to synchronize them so that my DAQ card will start and stop the acquisition definitely when the motion start and stop. This version of "FlexMotion4. In general NI's support answers quickly. supoose in my . The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Installing/reinstalling LV or CVI doesn't necessarily install NI-Motion. The onboard CPU uses an embedded real-time OS. Save on shipping. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. 08-10-2007 01:26 AM. 2. We presented a solution using the NI PCI-7344 four-axis stepper and servo motion controller using LabVIEW as the main user interface. option from the right-click menu. In my VI, I have called the Enable Limits. In the second part, you. This is a troubleshooting challenge. This compatibility allows the computer to automatically perform all bus-related configuration and requires no user interaction. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or. The program for our instrument is written with Labview 6 and we cannot afford to rewrite it. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. Options. 0 Kudos Message 1 of 7 (4,209 Views) Reply. Yes I am using a PCI-7344 controller. 我目前的系統是PCI-7344 + UMI7764 LabVIEW 8. 1 (NIMotion7. Cary, NC, USA. The onboard CPU uses an embedded real-time OS. The code is similar to the following: Timer1_Timer() Check the status of the I/Os on the PCI-7344 and update as necessary If Input1 is 'on' the set Input1=T. 1. At this point, NI Motion will only operate in LabView 32-bit independant of 32-bit or 64-bit OS. activate the INH output via software. . In your vi you are using Start Motion all the time. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. On the other hand please take into account that the PID loop is running much faster and in order to align the trajectory generation rate ( = 10 ms in contoured mode) and the PID rate (= up to 62,5 µs) the DSP is calculating interjacent setpoints at the rate of the. 240 MHz signal. The onboard CPU uses an embedded real-time OS. It takes 10-20 milliseconds to start the move after the trigger. The VIs send motion commands to the board and also monitor the position of the axis. Re: PCI-7344 motor interfacing help. The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. 2. . Hi, We have a MID7654/7652 servomotor power drive, a PCI 7344 motion control card and Flexmotion software. I have verified the connection is working. 40. Giridhar, everything is ok with your 7344. I am usi. NI-DAQmx. Go to the Axis Configuration option, under the desired axis (e. I would like to implement control algorithm on PCI 7344 (Don't want to use the built-in PID). . Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. 0. I've got a PCI card (PCI 7344 for motion control). We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. I want to implement dual/multi nozzle heat extruder. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences; Semiconductor;How easy is it to configure and program the Aerotech motion controllers using labview. 1) I successfully tuned the PID parameters so all the 4 motors are servoing now. 3. We built the entire machine to industrial standards for ruggedness, reliability, and minimal down time. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100PCI-7344, 4-Axis, Motion Controller National Instruments PCI-7344 Motion Controller DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. The capture method is configurable. 0 system with the newest NI-Motion 7. My DAQ is set as device 2 and my motion controller is set as board 1. You won't be able to achieve these types of signals with a 7344 motion control board. 6 on a separate desktop system with a PCI-7344 motion controller and a PCI-6221 DAQ card. PCI-7344を他社製のモータードライバに接続しようと思います。モータードライバのパルス入力の仕様で、パルス幅が10μSec以上となっているのですが、PCI-7344を接続して使うことはできますか?Using a PCI 7344 and three servos (with LabVIEW). The 7344 uses a 10. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. 0 and NI-Motion 7. When I was using a Motion Controller such as the PCI-7344 which uses the Motion driver, it was possible to save all the motor settings in a . We hardly ever use the INH outputs (the lines are disconnected) but in one case we do. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. 75 ms corresponding to 180 degrees. Options. can we get the VI for oscillator with variable frequency from 10 khz to 1 Mhz with variable duty cycle. . Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. Product Support Resources. 12 PCI 7344 MAX -Two-axis Configurations 39 3. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. I have seen a few other places where people have asked to do this but have found other solutions. The intent is to collect data at each grid point of an X-Y grid. The CPU-usage rises up to 100%. pci-7340 initialization problem. . I am planning to use PCI-7344 to implement speed control for 7,5 kW induction motor. . Find many great new & used options and get the best deals for National Instruments PCI-7344 Servo Controller Card at the best online prices at eBay! Free shipping for many products!Re: LabVIEWアップデートに伴うPCI-7344のエラー. The PCI‑7334 offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high-performance stepper generation for ensuring smooth. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. Cac cong I/O c tch hp san nh cac cong tac gii han hanh trnh, cac cong tac ho tr cho viec thiet lap goc toa o (Set home) may va mot so cho cac muc ch chung khac. 付属されていた新しいドライバCDはインストールしましたでしょうか?. There does not appear to be any built-in support for that device. Single-board rio oem devices (50 pages) The PCI-7344 is not a working device but something I created to explore the change board ID option. The analog signal can be from -10 to 10V. Hi all, I'm using the output pins of the 7344 - board. To provide on-line monitoring of the contact response, a multifunctional data acquisition board PCI-6251 (National Instruments Co. 1 . Fault+. The PCI‑7344 also provides contouring capability for complex moves. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Please. 2 version but I can't be initialize the motion card in MAX Discontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358 Solved: I install NI PCI-7344. Since, I'm waiting in a loop for the Move Complete bit, the program (VB 6. 10 NI UMI 7765 Universal Machine Interface Card 38 xu . After the update the card was not anymore detected in MAX. -While controlling the motors in the "Interactive control" tab, the position. 0 Kudos Message 1 of 4 (2,952 Views) Reply. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PCI-7390 Driver. Feel free to check it out here. Options. Im not very advanced with Lab. So the servo's torque reaches the target, it shoud be stopped at that postion unless any change in servo's torque happens. 00 +$12. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. But the MAX couldn't read the current traject. Applications Engineering Group. You won't be able to achieve these types of signals with a 7344 motion control board. It is related to 3D printer. 10. 3008 to 7. Sorry but I can't give you any further help. 8. I am using a PCI-7344 motion control card with a UMI-7764 break out box. Overview of the 1-D Interactive Panel. Hi, I am using a PCI-7344 with a UMI-7764 to try and control 3 linear actuators and 1 semi-rotary actuator, each of these actuators takes a 0-10v dc voltage and has a feedback signal of 0-10v dc, both input and output being proportional to linear/angular displacement. Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). This warranty includes parts and. Using PCI-7344 and MID-7604 and FLEXMOTION. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. Environment: MAX 3. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The fact is ,as most say,the driver is not suitable under non-windows systems. This motion controller can control upto 4 servo motors and can give 2 PWM. 0 and PCI-7344 motor.